2025-04-14 22:08:50 +03:00
|
|
|
using X86Disassembler.X86.Operands;
|
|
|
|
|
2025-04-13 00:28:12 +03:00
|
|
|
namespace X86Disassembler.X86.Handlers.Or;
|
2025-04-12 20:13:01 +03:00
|
|
|
|
|
|
|
/// <summary>
|
|
|
|
/// Handler for OR r/m8, imm8 instruction (0x80 /1)
|
|
|
|
/// </summary>
|
2025-04-12 23:03:07 +03:00
|
|
|
public class OrImmToRm8Handler : InstructionHandler
|
2025-04-12 20:13:01 +03:00
|
|
|
{
|
|
|
|
/// <summary>
|
|
|
|
/// Initializes a new instance of the OrImmToRm8Handler class
|
|
|
|
/// </summary>
|
|
|
|
/// <param name="decoder">The instruction decoder that owns this handler</param>
|
2025-04-14 22:08:50 +03:00
|
|
|
public OrImmToRm8Handler(InstructionDecoder decoder)
|
|
|
|
: base(decoder)
|
2025-04-12 20:13:01 +03:00
|
|
|
{
|
|
|
|
}
|
2025-04-13 23:06:52 +03:00
|
|
|
|
2025-04-12 20:13:01 +03:00
|
|
|
/// <summary>
|
|
|
|
/// Checks if this handler can decode the given opcode
|
|
|
|
/// </summary>
|
|
|
|
/// <param name="opcode">The opcode to check</param>
|
|
|
|
/// <returns>True if this handler can decode the opcode</returns>
|
|
|
|
public override bool CanHandle(byte opcode)
|
|
|
|
{
|
|
|
|
if (opcode != 0x80)
|
|
|
|
return false;
|
2025-04-13 23:06:52 +03:00
|
|
|
|
2025-04-12 20:13:01 +03:00
|
|
|
// Check if the reg field of the ModR/M byte is 1 (OR)
|
2025-04-14 01:08:14 +03:00
|
|
|
if (!Decoder.CanReadByte())
|
2025-04-12 20:13:01 +03:00
|
|
|
return false;
|
2025-04-13 23:06:52 +03:00
|
|
|
|
2025-04-15 02:42:47 +03:00
|
|
|
var reg = ModRMDecoder.PeakModRMReg();
|
2025-04-13 23:06:52 +03:00
|
|
|
|
2025-04-12 20:13:01 +03:00
|
|
|
return reg == 1; // 1 = OR
|
|
|
|
}
|
2025-04-13 23:06:52 +03:00
|
|
|
|
2025-04-12 20:13:01 +03:00
|
|
|
/// <summary>
|
|
|
|
/// Decodes an OR r/m8, imm8 instruction
|
|
|
|
/// </summary>
|
|
|
|
/// <param name="opcode">The opcode of the instruction</param>
|
|
|
|
/// <param name="instruction">The instruction object to populate</param>
|
|
|
|
/// <returns>True if the instruction was successfully decoded</returns>
|
|
|
|
public override bool Decode(byte opcode, Instruction instruction)
|
|
|
|
{
|
2025-04-14 22:08:50 +03:00
|
|
|
// Set the instruction type
|
|
|
|
instruction.Type = InstructionType.Or;
|
2025-04-13 23:06:52 +03:00
|
|
|
|
2025-04-14 01:08:14 +03:00
|
|
|
if (!Decoder.CanReadByte())
|
2025-04-12 20:13:01 +03:00
|
|
|
{
|
|
|
|
return false;
|
|
|
|
}
|
2025-04-13 23:06:52 +03:00
|
|
|
|
2025-04-12 20:13:01 +03:00
|
|
|
// Read the ModR/M byte
|
2025-04-14 22:08:50 +03:00
|
|
|
// For OR r/m8, imm8 (0x80 /1):
|
|
|
|
// - The r/m field with mod specifies the destination operand (register or memory)
|
|
|
|
// - The immediate value is the source operand
|
2025-04-15 02:42:47 +03:00
|
|
|
var (_, _, _, destinationOperand) = ModRMDecoder.ReadModRM();
|
2025-04-14 22:08:50 +03:00
|
|
|
|
|
|
|
// Adjust the operand size to 8-bit
|
|
|
|
destinationOperand.Size = 8;
|
2025-04-13 23:06:52 +03:00
|
|
|
|
2025-04-14 01:08:14 +03:00
|
|
|
// Read the immediate value
|
|
|
|
if (!Decoder.CanReadByte())
|
2025-04-12 20:13:01 +03:00
|
|
|
{
|
|
|
|
return false;
|
|
|
|
}
|
2025-04-13 23:06:52 +03:00
|
|
|
|
|
|
|
// Read the immediate value
|
|
|
|
byte imm8 = Decoder.ReadByte();
|
2025-04-14 22:08:50 +03:00
|
|
|
|
|
|
|
// Create the source immediate operand
|
|
|
|
var sourceOperand = OperandFactory.CreateImmediateOperand(imm8, 8);
|
|
|
|
|
|
|
|
// Set the structured operands
|
|
|
|
instruction.StructuredOperands =
|
|
|
|
[
|
|
|
|
destinationOperand,
|
|
|
|
sourceOperand
|
|
|
|
];
|
2025-04-13 23:06:52 +03:00
|
|
|
|
2025-04-12 20:13:01 +03:00
|
|
|
return true;
|
|
|
|
}
|
2025-04-13 23:06:52 +03:00
|
|
|
}
|