mirror of
https://github.com/sampletext32/ParkanPlayground.git
synced 2025-05-19 20:01:17 +03:00
78 lines
2.4 KiB
C#
78 lines
2.4 KiB
C#
namespace X86Disassembler.X86.Handlers.Test;
|
|
|
|
/// <summary>
|
|
/// Handler for TEST r/m32, imm32 instruction (0xF7 /0)
|
|
/// </summary>
|
|
public class TestImmWithRm32Handler : InstructionHandler
|
|
{
|
|
/// <summary>
|
|
/// Initializes a new instance of the TestImmWithRm32Handler class
|
|
/// </summary>
|
|
/// <param name="codeBuffer">The buffer containing the code to decode</param>
|
|
/// <param name="decoder">The instruction decoder that owns this handler</param>
|
|
/// <param name="length">The length of the buffer</param>
|
|
public TestImmWithRm32Handler(byte[] codeBuffer, InstructionDecoder decoder, int length)
|
|
: base(codeBuffer, decoder, length)
|
|
{
|
|
}
|
|
|
|
/// <summary>
|
|
/// Checks if this handler can decode the given opcode
|
|
/// </summary>
|
|
/// <param name="opcode">The opcode to check</param>
|
|
/// <returns>True if this handler can decode the opcode</returns>
|
|
public override bool CanHandle(byte opcode)
|
|
{
|
|
// This handler only handles opcode 0xF7
|
|
if (opcode != 0xF7)
|
|
{
|
|
return false;
|
|
}
|
|
|
|
// Check if we have enough bytes to read the ModR/M byte
|
|
if (!Decoder.CanReadByte())
|
|
{
|
|
return false;
|
|
}
|
|
|
|
// Check if the reg field is 0 (TEST operation)
|
|
byte modRM = CodeBuffer[Decoder.GetPosition()];
|
|
byte reg = (byte)((modRM & 0x38) >> 3);
|
|
|
|
return reg == 0; // 0 = TEST
|
|
}
|
|
|
|
/// <summary>
|
|
/// Decodes a TEST r/m32, imm32 instruction
|
|
/// </summary>
|
|
/// <param name="opcode">The opcode of the instruction</param>
|
|
/// <param name="instruction">The instruction object to populate</param>
|
|
/// <returns>True if the instruction was successfully decoded</returns>
|
|
public override bool Decode(byte opcode, Instruction instruction)
|
|
{
|
|
// Set the mnemonic
|
|
instruction.Mnemonic = "test";
|
|
|
|
// Read the ModR/M byte
|
|
var (mod, reg, rm, destOperand) = ModRMDecoder.ReadModRM();
|
|
|
|
// For direct register addressing (mod == 3), the r/m field specifies a register
|
|
if (mod == 3)
|
|
{
|
|
destOperand = ModRMDecoder.GetRegisterName(rm, 32);
|
|
}
|
|
|
|
// Read the immediate value
|
|
if (!Decoder.CanReadUInt())
|
|
{
|
|
return false;
|
|
}
|
|
|
|
uint imm32 = Decoder.ReadUInt32();
|
|
|
|
// Set the operands
|
|
instruction.Operands = $"{destOperand}, 0x{imm32:X8}";
|
|
|
|
return true;
|
|
}
|
|
} |